Product Introduction
F72B-ACB AC Ammeter and Voltmeter with Alarm Output Features: Used for measuring AC current and voltage and providing over-limit alarm output. Accuracy: 1.5 Ambient Temperature: -25℃ to +55℃ Enclosure Protection: IP44 (IP65 with protective cover; must be specified in order). Vibration Resistance: 2-100Hz, ≤0.7g Withstand Voltage: AC2.5kV, 50Hz, 1min Power Consumption: ≤0.7g Auxiliary Power Supply: Un±15% (un: 100V, 220V, 380V) Output Contact Capacity: AC250V, 1A, DC28V, 1A Alarm Point Setting: Can be set to upper limit, lower limit, and both upper and lower limits Measurement Range: F96-AC
Specifications
F72B-ACB AC Ammeter and Voltmeter with Alarm Output Features:
Used for measuring AC current and voltage, and providing over-limit alarm output.
Accuracy: 1.5
Ambient Temperature: -25℃ to +55℃
Enclosure Protection: IP44 (IP65 with protective cover; must be specified when ordering).
Vibration resistance: 2-100Hz, ≤0.7g
Voltage withstand: AC2.5kV, 50Hz, 1min
Power consumption: ≤0.7g
Auxiliary power supply: Un±15% (un: 100V, 220V, 380V)
Output contact capacity: AC250V, 1A, DC28V, 1A
Alarm point setting: Can be configured as upper limit, lower limit, and both upper and lower limits
Measuring range: F96-AC
Product category:
Model
Expansion angle
Dimensions
(A*B*C)
Opening size
(mm)
Weight
(kg)
Remarks
F72B-ACB
90°
72*72*85
68*68+0.5
0.2
Compatible with YT-GD or YT-GDCJ type external transmitters
By YT-GCJ or YT-GDUJ external Converter
F96B-DCB
96*96*130
92*92+0.5
0.5
…
F72B-AC
240°
72*72*85
68*68+0.5
0.4
Used with YT-GD or YT-GDCJ type external transmitters
By YT-GCJ or YT-GDUJ external converter
F96B-AC
96*96*130
92*92+0.5
0.7
…
1. Limit instruments not listed in the specification sheet can also be supplied. Users must specify this when ordering and confirm it in the contract.
2. Instruments can be customized with a red line drawn at the setpoint or made with a red setpoint pointer, according to user requirements.
3. The standard frequency of the instrument is 50Hz. Instruments with frequencies of 60Hz or 400Hz can be manufactured according to user requirements. Users must specify this when ordering and confirm it in the contract.
4. The instrument's terminal block arrangement is shown in Figures 2.2 and 2.3.
5. Use normally closed contacts for lower limit alarms; use normally open contacts for upper limit alarms.
6. For special purpose instruments, please add "J" after the first half of the model number (limited to 240° instruments), such as: F96J-AC