F72B-AC AC Ammeter and Voltmeter with Alarm Output

Product Introduction

F72B-AC AC Ammeter and Voltmeter with Alarm Output Features: Used for measuring AC current and voltage and providing over-limit alarm output. Accuracy: 1.5 Ambient Temperature: -25℃ to +55℃ Enclosure Protection: IP44 (IP65 with protective cover; must be specified in order). Vibration Resistance: 2-100Hz, ≤0.7g Withstand Voltage: AC2.5kV, 50Hz, 1min Power Consumption: ≤0.7g Auxiliary Power Supply: Un±15% (un: 100V, 220V, 380V) Output Contact Capacity: AC250V, 1A, DC28V, 1A Alarm Point Setting: Can be set to upper limit, lower limit, and both upper and lower limits Measurement Range: F96-AC

Specifications

F72B-AC AC Ammeter and Voltmeter with Alarm Output Characteristics:

Used for measuring AC current and voltage and providing over-limit alarm output.

Accuracy: 1.5

Ambient Temperature: -25℃ to +55℃

Enclosure Protection: IP44 (IP65 with protective cover; must be specified in order).

Vibration Resistance: 2-100Hz, ≤0.7g

Voltage Withstand: AC2.5kV, 50Hz, 1min

Power Consumption: ≤0.7g

Auxiliary Power Supply: Un±15% (un: 100V, 220V, 380V)

Output Contact Capacity: AC250V, 1A, DC28V, 1A

Alarm Point Setting: Can be configured with upper limit, lower limit, and both upper and lower limits.

Measuring Range: F96-AC

Product Category:

Model Number Development Angle Overall Dimensions Opening Size Weight             Remarks
(A*B*C) (mm) (kg)
F72B-ACB 90° 72*72*85 68*68+0.5 0.2 Use with YT-GD or YT-GDCJ type external transmitter
By YT-GCJorYT-GDUJexternal converter
F96B-DCB 96*96*130 92*92+0.5 0.5           …
F72B-AC 240° 72*72*85 68*68+0.5 0.4 Use with YT-GD or YT-GDCJ type external transmitter
By YT-GCJorYT-GDUJexternal converter
F96B-AC 96*96*130 92*92+0.5 0.7            ...

1. Measuring instruments not listed in the specification sheet can also be supplied. The user must specify this when ordering and confirm it in the contract.

2. Meters can be customized by marking a red line at the setpoint or by manufacturing instruments with a red setpoint pointer, as required by the user.

3. The standard frequency of the instrument is 50Hz. Meters can be manufactured for 60Hz or 400Hz upon request. The user must specify this when ordering and confirm it in the contract.

4. The terminal block arrangement of the instrument is shown in Figures 2.2 and 2.3.

5. Use normally closed contacts for lower limit alarms; use normally open contacts for upper limit alarms.

6. For special purpose instruments, please add "J" after the numbers in the first half of the model number (limited to 240° instruments only), e.g., F96J-AC