F96-S Synchronizing Indicator

Product Overview

F96-S Synchronoscope: This series of meters consists of direct-acting electrical measuring instruments featuring analog displays. They are utilized in various AC and DC power transmission and distribution systems, control panels, and electrical equipment to measure electrical parameters—such as AC and DC current, voltage, frequency, power factor, and insulation resistance—as well as to provide synchronization indication. Additionally, they serve to provide electrical measurement indications for non-electrical parameters in other systems.

Specifications

F96-S Synchronoscope

F96-DC DC Ammeter, Q96-DC DC Ammeter, F72-DC DC Ammeter, Q72-ZC DC Ammeter, 51C5-A DC Ammeter, 51C6-A DC Ammeter, 61C13-A DC Ammeter, 61C14-A DC Ammeter,
F96-DC DC Voltmeter, Q96-ZC DC Voltmeter, F72-DC DC Voltmeter, Q72-ZC DC Voltmeter, 51C5-V DC Voltmeter, 51C6-V DC Voltmeter, 61C13-V DC Voltmeter, 61C14-V DC Voltmeter,
F96-X Non-electrical Parameter Meter, Q96-X Non-electrical Parameter Meter, F72-X Non-electrical Parameter Meter, Q72-X Non-electrical Parameter Meter
F96-AC AC Ammeter, Q96-RZC AC Ammeter, F72-AC AC Ammeter, Q72-RZC AC Ammeter, 51L5-A AC Ammeter, 51L6-A AC Ammeter, 61L13-A AC Ammeter, 61L14-A AC Ammeter,
F96-AC AC Voltmeter, Q96-RZC AC Voltmeter, F72-AC AC... Voltmeters: Q72-RZC AC Voltmeter, 51L5-V AC Voltmeter, 51L6-V AC Voltmeter, 61L13-V AC Voltmeter, 61L14-V AC Voltmeter,
Overload Ammeters: F96-AC-A1 AC Overload Ammeter, Q96-RZC-A1 AC Overload Ammeter, F72-AC-A1 AC Overload Ammeter, Q72-RZC-A1 AC Overload Ammeter, 51L5-A1 AC Overload Ammeter, 51L6-A1 AC Overload Ammeter, 61L13-A1 AC Overload Ammeter, 61L14-A1 AC Overload Ammeter,
3-Phase Active Power Meters: F96-W 3-Phase Active Power Meter, Q96-WTCZA 3-Phase Active Power Meter, F72-W 3-Phase Active Power Meter, Q72-WTCZA 3-Phase Active Power Meter, 51L5-W 3-Phase Active Power Meter, 51L6-W 3-Phase Active Power Meter, 61L13-W 3-Phase Active Power Meter, 61L14-W 3-Phase Active Power Meter,
3-Phase Reactive Power Meters: F96-VAR 3-Phase Reactive Power Meter, Q96-YTCZA 3-Phase Reactive Power Meter, F72-VAR 3-Phase Reactive Power Meter, Q72-YTCZA 3-Phase Reactive Power Meter, 51L5-V AR 3-Phase Reactive Power Meter, 51L6-VAR 3-Phase Reactive Power Meter, 61L13-VAR 3-Phase Reactive Power Meter, 61L14-VAR 3-Phase Reactive Power Meter,
F96-COSΦ Single-Phase Power Factor Meter, Q96-FTZ Single-Phase Power Factor Meter, F72-COSΦ Single-Phase Power Factor Meter, Q72-FTZ Single-Phase Power Factor Meter, 51L5-COSΦ Single-Phase Power Factor Meter, 51L6-COSΦ Single-Phase Power Factor Meter, 61L13-COSΦ Single-Phase Power Factor Meter, 61L14-COSΦ Single-Phase Power Factor Meter,
F96-COSΦ 3-Phase Power Factor Meter, Q96-FTZ 3-Phase Power Factor Meter, F72-COSΦ 3-Phase Power Factor Meter, Q72-FTZ 3-Phase Power Factor Meter, 51L5-COSΦ 3-Phase Power Factor Meter, 51L6-COSΦ 3-Phase Power Factor Meter, 61L13-COSΦ 3-Phase Power Factor Meter, 61L14-COSΦ 3-Phase Power Factor Meter,
F96-HZ Frequency Meter, Q96-HZC Frequency Meter, F72-HZ Frequency Meter, Q72-HZC Frequency Meter, 51L5-HZ Frequency Meter, 51L6-HZ Frequency Meter Meters; 61L13-Hz Frequency Meter; 61L14-Hz Frequency Meter;
F96-S Synchronoscope; Q96-S Synchronoscope; F72-S Synchronoscope; Q72-S Synchronoscope; 51T5-S Synchronoscope; 51T6-S Synchronoscope; 61T13-S Synchronoscope; 61T14-S Synchronoscope;
F96-MΩ High-Resistance Meter; Q96-MΩ High-Resistance Meter; F72-MΩ High-Resistance Meter; Q72-MΩ High-Resistance Meter; 51C5-MΩ High-Resistance Meter; 51C6-MΩ High-Resistance Meter; 61C13-MΩ High-Resistance Meter; 61C14-MΩ High-Resistance Meter;
F96-BMΩ High-Resistance Meter; Q96-BMΩ High-Resistance Meter; F72-BMΩ High-Resistance Meter; Q72-BMΩ High-Resistance Meter; 51L5-BMΩ High-Resistance Meter; 51L6-BMΩ High-Resistance Meter; 61L13-BMΩ High-Resistance Meter; 61L14-BMΩ High-Resistance Meter;
F96-℃ Temperature Meter; Q96-℃ Temperature Meter; F72-℃ Temperature Meter; Q72-℃ Temperature Meter; 51C5-℃ Temperature Meter; 51C6-℃ Temperature Meter; 61C13-℃ Temperature Meter; 61C14-℃ Temperature Meter;

1. Application
F96-S Synchronoscope: This series of meters consists of analog-display, direct-acting electrical measuring instruments. They are used in various AC/DC power transmission and distribution systems, control panels, and electrical equipment to measure electrical parameters—such as AC/DC current, voltage, frequency, power factor, and insulation resistance—as well as for synchronization indication. Additionally, they serve to provide electrical measurement indications for non-electrical parameters within other systems.
2. Technical Parameters
2.1  The measuring mechanism of this meter series employs either a magnetoelectric system with taut-band suspension or a magnetoelectric system with a pivot-and-jewel bearing structure. Taut-band Suspension: The rotating assembly is friction-free, ensuring reliable operation and high resistance to mechanical shock. The pivot-and-jewel structure—featuring a spring-loaded bearing system to cushion and dampen the moving parts—utilizes high-hardness cobalt-tungsten alloy for the pivots and corundum jewels for the bearings, thereby endowing the instrument with exceptional resistance to vibration fatigue, mechanical shock, and wear.
2.2 The instrument features an integrated design that combines the transducer circuitry with the indicating mechanism, resulting in high measurement accuracy and a wide deflection angle.
2.3 This series comprises moving-coil instruments characterized by a highly linear scale and immunity to external magnetic fields. All models feature printed dials—including color-coded scales (using colored lines, bands, and numerals)—ensuring clear graduations and a clean, aesthetically pleasing dial face.
2.4 This series of electrical meters offers a comprehensive range of options; in addition to standard electrical measurement specifications, it includes various specialized instruments such as expanded-scale meters, overload meters, single-scale meters, control-signal meters, and instruments designed for the electrical measurement of non-electrical parameters.
2.5 All instruments featuring a zero-point reading are equipped with a front-mounted zero-adjustment knob, allowing for convenient and flexible zero-setting.
2.6 Featuring a standardized physical design, the external dimensions of this instrument series are based on a modular unit of 12. The square-faced profile ensures an attractive appearance while facilitating convenient layout and installation within control panels and cabinets.

Feedback