F96-DCB DC Voltmeter

Product Overview

F96-DCB DC Voltmeter — Features: Designed for the measurement of DC voltage. Accuracy: 1.5. Ambient Temperature: -25°C to +55°C. Enclosure Protection: IP44 (IP56 achievable with the addition of a protective cover; must be specified when ordering). Vibration Resistance: 2–100 Hz, ≤0.9g. Dielectric Strength: AC 2.5 kV, 50 Hz, 1 min. Voltmeter Internal Resistance: 1 kΩ/V.

Specifications

F96-DCB DC Voltmeter
Features:
Used for the measurement of DC voltage.
Accuracy: 1.5
Ambient Temperature: -25°C to +55°C
Enclosure Protection: IP44 (IP56 achievable with the addition of a protective cover; must be specified when ordering)
Vibration Resistance: 2–100 Hz, ≤0.9g
Withstand Voltage: AC 2.5 kV, 50 Hz, 1 min
Voltmeter Internal Resistance: 1 kΩ/V

Specifications Table:

Direct Voltage Input Input via an external 75 mV fixed-value shunt
mA 0.5~500 A 5~750
A 1~5 KA 1~10
mV 100~600 Secondary Indicating Instrument  
V 1~600 4~20Ma,1.5V  

Resistance of the fixed-value connecting wires between the external shunt and the meter head ≤ 0.035 Ω.

Product Category:

Model Opening Angle Overall Dimensions A×B×C (mm) Cutout Dimensions (mm) Weight (kg)
F48-DCB F48-DCB(G) 90° 48*48*65 45*45+0.5 0.1
F72-DCB F72-DCB(G) 72*72*85 68*68+0.5 0.15
F80H-DCB F80H-DCB(G) 80*60*65 74*54+0.5 0.15
F96-DCB F96-DCB(G) 96*96*85 92*92+0.5 0.2
F144-DCB F144-DCB(G) 144*144*85 138*138+0.5 0.25
69C7-A 69C7-V 80*60*68 φ54+0.5 0.1
F96H-DC F96H-DC(G)     60°Horizontal Tank 48*96*130 45*92+0.5 0.3
F120H-DC F120H-DC(G)     105° 120*96*65 116*92+0.5 0.25
F72-DC F72-DC(G)   72*72*85 68*68+0.5 0.3
F96-DC F96-DC(G)   96*96*85 92*92+0.5 0.4
F144-DC F144-DC(G)   144*144*85 138*138+0.5 0.5
45C3-A 45C3-V   120*120*91 picture Figure2 0.9

Notes:
1. Instruments with ranges other than those listed in the specifications table are available upon request; users must specify such requirements when placing an order, and these details must be formally confirmed within the contract.
2. Instruments can be manufactured with a bidirectional indication design, featuring a zero point positioned at the center of the scale.
3. Upon user request, a red line can be marked at a specific setpoint value, or the instrument can be manufactured with a red setpoint pointer.
4. Instruments with special specifications can be manufactured to meet user requirements—such as those featuring a single scale with dual readings, or colored dials (e.g., green or red scale lines and characters).
5. The (G) model features a black faceplate with internal illumination; alternatively, a white faceplate with internal illumination can be manufactured upon user request.
6. For instruments intended for special applications, please append the suffix "J" immediately following the numerical portion of the model number (this option is limited to 240° instruments only); for example: F96J-DC. 