F72MB-DCTB Temperature Gauge with Transmitter and Alarm Output

Product Introduction

F72MB-DCTB Temperature Gauge with Transmitter and Alarm Output Features: Input Signal: PT100, K-type thermocouple Accuracy: 1.5 Ambient Temperature: -25℃ to +55℃ Enclosure Protection: IP44 (IP65 with protective cover; must be specified in order). Vibration Resistance: 2-100Hz, ≤0.7g Withstand Voltage: AC2.5kV, 50Hz, 1min Operating Power Supply: 24Vdc±25%, 100Vac, 220Vac+20% Power Consumption: ≤2VA Output Contact Capacity: AC250V, 1A, DC28V, 1A Alarm Point Setting: Can be configured with upper limit, lower limit, and peak lower limit according to user requirements. Measurement range is the same as F96-DCT.

Specifications

F72MB-DCTB Temperature Gauge with Transmitter and Alarm Output

Features:

Input Signal: PT100, K-type thermocouple

Accuracy: 1.5

Ambient Temperature: -25℃ to +55℃

Enclosure Protection: IP44 (IP65 with protective cover; must be specified in order).

Vibration Resistance: 2-100Hz, ≤0.7g

Voltage Withstand: AC2.5kV, 50Hz, 1min

Operating Power Supply: 24Vdc±25%, 100Vac, 220Vac+20%

Power Consumption: ≤2VA

Output Contact Capacity: AC250V, 1A, DC28V, 1A

Alarm Point Setting: Can be configured with upper limit, lower limit, and peak lower limit according to user requirements.

Measurement range is the same as F96-DCT.

Product Category:

Model

Expansion Angle

External Dimensions (A*B*C)

Opening Size (mm)

Weight (kg)

F72-DCTB

90°

72*72*120

68*68+0.5

0.3

F96-DCTB

96*96*130

92*92+0.5

0.4

F144-DCTB

144*144*130

138*138+0.5

0.45

F72B-DCT

240°

72*72*120

68*68+0.5

0.5

F96B-DCT

96*96*130

92*92+0.5

0.5

F144 B-DTC

144*144*130

138*138+0.5

0.6

Note:

Limit instruments not listed in the specification sheet can also be supplied. Users must specify this when ordering and confirm it in the contract.

See Figure 10.2 for instrument terminal block arrangement.

Users should specify the model, specifications, power supply, alarm values, and other parameters when ordering, and specify and confirm these in the contract.

For special purpose instruments, please add "J" after the first half of the model number (only applicable to 240° instruments), such as F96JB-DCT.