Product Overview
F72-ACB AC Ammeter Features: Designed for the measurement of AC current and voltage. Accuracy: Class 1.5. Ambient Temperature: -25°C to +55°C. Enclosure Protection: IP44 (IP65 achievable with the addition of a protective cover; must be specified when ordering). Vibration Resistance: 2–100 Hz, ≤0.7g. Withstand Voltage: AC 2.5 kV, 50 Hz, 1 min. Ammeter Power Consumption: ≤0.5 VA. Voltmeter Power Consumption: ≤0.006 UVA.
Specifications
F72-ACB AC Ammeter Features:
Used for the measurement of AC current and voltage.
Accuracy Class: 1.5
Ambient Temperature: -25°C to +55°C
Enclosure Protection: IP44 (IP65 achievable with the addition of a protective cover; must be specified when ordering).
Vibration Resistance: 2–100 Hz, ≤0.7g
Withstand Voltage: AC 2.5 kV, 50 Hz, 1 min
Ammeter Power Consumption: ≤0.5 VA
Voltmeter Power Consumption: ≤0.006 VA
Specification Table:
| Direct Connection | Input via 1/5A Current Transformers | ||
| A | 0.5~20 | A | 10~800 |
| V | 30~600 | KA | 1~10 |
| Input via U/100V Voltage Transformers | Overload Ammeter | ||
| V | 450 | 1A-(2~6) | 5A-(10~30)A |
| Kv | 3~42 | ||
Product Categories:
| Model | Opening Angle | Overall Dimensions | Cutout Dimensions | Weight |
| (A*B*C) | (mm) | (kg) | ||
| F48-ACB F48-ACB(G) | 90° | 48*48*65 | 45*45+0.5 | 0.2 |
| F72-ACB F72-ACB(G) | 72*72*120 | 68*68+0.5 | 0.25 | |
| F80H-ACB F80H-ACB(G) | 80*60*65 | 74*54+0.5 | 0.25 | |
| F96-ACB F96-ACB(G) | 96*96*85 | 92*92+0.5 | 0.3 | |
| F144-DCB F144-DCB(G) | 144*144*85 | 138*138+0.5 | 0.35 | |
| 69L7-A 69L7-V | 80*60*68 | φ54+0.5 | 0.2 | |
| F96H-AC F96H-AC(G) | 60(Slot Profile) | 48*96*130 | 45*92+0.5 | 0.3 |
| F120H-AC F120H-AC(G) | 105° | 120*96*65 | 116*92+0.5 | 0.25 |
| F72-ACB F72-AC(G) | 240° | 72*72*120 | 68*68+0.5 | 0.4 |
| F96-AC F96-AC(G) | 96*96*85 | 92*92+0.5 | 0.5 | |
| F144-AC F144-AC(G) | 144*144*85 | 138*138+0.5 | 0.55 | |
| 45L1-A 45-L1-V | 120*120*91 | picture 2 | 1 | |
| F96D-ACB | 90° | 96*96*130 | 92*92+0.5 | 0.5 |
| F72D-ACB | 72*72*120 | 68*68+0.5 | 0.4 | |
| F144D-ACB | 144*144*85 | 138*138+0.5 | 0.8 |
Notes:
1. Instruments with ranges other than those listed in the specifications table can be supplied; users must specify such requirements when placing an order, and these details must be confirmed within the contract.
2. Upon user request, a red line can be marked at a specific setpoint on the instrument dial, or the instrument can be manufactured with a red setpoint pointer.
3. The standard operating frequency for these instruments is 50 Hz; however, units configured for 60 Hz or 400 Hz can be manufactured upon user request. Users must specify such requirements when placing an order, and these details must be confirmed within the contract.
4. The (G) model features a black dial face with internal illumination; however, units with a white dial face and internal illumination can also be manufactured upon user request.
5. For instruments intended for special applications, please append the letter "J" after the numerical portion of the model designation (applicable to 240° scale instruments); for example: F96J-AC.